Experimental study on optimum performance of two-stage air-heated bubble-column humidification–dehumidification system
DOI:
https://doi.org/10.17159/wsa/2023.v49.i4.4009Keywords:
thermal desalination, two-stage HDH, bubble column humidifier and dehumidifier, response surface methodology, optimizationAbstract
An experimental investigation of a small-scale air-heated humidification–dehumidification (HDH) desalination system with bubble-column humidification and dehumidification units was conducted. The study addressed the performance of the multistage air-heated bubble-column HDH system, which has limited coverage in the literature, by operating two bubble-column humidifiers in series for the air humidification process with air reheating. The effect of operating parameters such as airflow rate, air temperature, and saline water levels in both humidifiers on the performance metrics of the system were investigated. The product distillate rate, energy consumption, gain output ratio (GOR), and specific energy consumption (SEC) are the main indicators of performance for the proposed desalination system. Response surface methodology (RSM) was applied to the current system using the design of experiment (DoE) for the prediction of variables that greatlyaffect productivity and energy input. The airflow rate, air temperature, and water level of the second humidifier have a favourable effect on the distillate rate and GOR of the system. In contrast, the effect of the water level inside the first humidifier is insignificant. Furthermore, the RSM optimization approach was used to obtain the optimum distillate productivity. An optimized distillate rate of 0.45 L/h and a GOR of 0.4 are achieved at 1.5 SCFM (standard cubic feet per minute) of airflow rate, and 6.5 cm of water level in the second humidifier with 140°C air inlet temperature. The numerical optimization reveals the optimal operating parameters, that correspond to maximum distillate production of 0.3 L/h with minimum input energy of 0.71 kW, to be 139°C air temperature, 1.13 SCFM of airflow rate, 6.5 cm and 3 cm water levels of second and first humidifier, respectively.
Downloads
Downloads
Published
Issue
Section
License
Copyright (c) 2023 Majid Khan, M Faizan, Mohamed A Antar, Atia E Khalifa
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
The content of this journal is licensed under a Creative Commons Attribution Licence. Users are permitted to read, download, copy, distribute, print, search or link to the full texts of the articles in this journal under the terms of this Licence, without asking prior permission from the publisher or the author, provided the source is attributed. Copyright is retained by the authors.