In-line rheological characterisation of wastewater sludges using non-invasive ultrasound sensor technology

Authors

  • R Kotzé Flow Process & Rheology Centre (FPRC), Cape Peninsula University of Technology, PO Box 652, Cape Town, 8000, South Africa
  • R Haldenwang Flow Process & Rheology Centre (FPRC), Cape Peninsula University of Technology, PO Box 652, Cape Town, 8000, South Africa
  • V Fester Flow Process & Rheology Centre (FPRC), Cape Peninsula University of Technology, PO Box 652, Cape Town, 8000, South Africa
  • W Rössle Wastewater Branch, Water and Sanitation Department, City of Cape Town, 38 Wale Street, Cape Town, South Africa

DOI:

https://doi.org/10.4314/wsa.v41i5.11

Keywords:

ultrasonic velocity profiling, UVP PD methodology, sludge rheology, non-Newtonian, tube viscometry, non-invasive, sludge dewaterin

Abstract

The performance of a new ultrasound transducer, which can measure velocity profiles non-invasively through high-grade stainless steel pipes, was evaluated for the first time with secondary wastewater sludges. This work is a follow-up study on the feasibility work initially done by the same authors. In-line process control based on accurate rheological characterisation for treated wastewater sludge could lead to significant savings in chemicals and will optimise dewatering processes producing drier sludges. In this work, a wastewater sludge at three concentrations was tested in order to investigate the capabilities of the in-line ultrasound technique for different viscosities and fluid properties. The rheological parameters obtained using the new ultrasound sensor and ultrasonic velocity profiling with combined pressure difference (UVP + PD) technique were compared with results obtained using conventional tube viscometry. Comparison with tube viscometer results showed that yield stresses could be overestimated by 120% if data are not available in the low shear-rate ranges. This non-invasive transducer proved to be sensitive enough to obtain flow curves over a large shear-rate range, improving the prediction of the yield stress and requiring about 50% less energy than the invasive system.

Downloads

Download data is not yet available.

Downloads

Published

2015-10-29

How to Cite

R Kotzé, R Haldenwang, V Fester, & W Rössle. (2015). In-line rheological characterisation of wastewater sludges using non-invasive ultrasound sensor technology. Water SA, 41(5 October). https://doi.org/10.4314/wsa.v41i5.11

Issue

Section

Research paper